Model
|
WWS03A-12
|
WWS06A-24
|
Rated Battery Voltage
|
12V
|
24V
|
Rated Wind Turbine Power
|
300W
|
600W
|
Wind Turbine Maximum Input Current
|
40A
|
40A
|
Wind Turbine Maximum Input Power
|
500W
|
1000W
|
Unload Voltage(factory default)
|
14V
|
28V
|
Unload Current(factory default)
|
25A
|
25A
|
PV Charge Current
|
10A
|
10A
|
Battery Over-discharge Voltage Shutoff
|
11V
|
22V
|
Battery Over-discharge Recovery
|
12V
|
24V
|
Output Protection Voltage
|
16V
|
32V
|
PV Voltage Of Light-Control On
|
Adjustable(1V)
|
Adjustable(2V)
|
PV Voltage Of Light-Control Off
|
Adjustable(1.5V)
|
Adjustable(3V)
|
Line 1 Rated Output Current
|
10A
|
10A
|
Line 2 Rated Output Current
|
10A
|
10A
|
Line 1 Output Mode(Factory Default)
|
3 Modes selection(Light-control on and Light-control off)
|
3 Modes selection(Light-control on and Light-control off)
|
Line 2 Output Mode(Factory Default)
|
3 Modes selection(Light-control on and time-control 5 hours)
|
3 Modes selection(Light-control on and time-control 5 hours)
|
Control Mode
|
PWM
|
|
Display Mode
|
LCD
|
|
Display Parameters
|
Wind Turbine Power,Wind Turbine Voltage,Wind Turbine Current,PV Voltage、PV Charge Current,PV Power, Battery Voltage,
Ove-Voltage,Under-Voltage, Over-load, short circuit.Etc
|
|
Working Temperature &Humidity
|
-20~+55℃/35~85%RH(Without Condensation)
|
|
Quiescent Current
|
20±2 mA
|
|
Protection Function
|
Solar reverse-charging protection , solar reverse-connection protection,
battery over charge protection,battery over-discharge protection,
battery reverse-connection protection, lightning protecting,
wind turbine current limitting, wind turbine automatic brake and manual brake.
|
|
In order to serve our customers better.Our company can adjust parameters configuration according to customer’s requirement.
|